Steel Roof System
A complete roof installation with load-bearing trusses, purlins and roofing.
- Color
- RAL of your choice to match the roofing
- Style
- Modern

01Model
What is this model for?
A steel roof is not a single product but three layers working together: the truss that carries the load, the purlins that hold the roofing and the roofing on top. Truss span and roof pitch are determined by the region’s snow and wind loads; along Istanbul’s northern belt wind dominates, while inland it is the snow load. Purlin spacing is directly tied to the roofing type — sandwich panel can handle wider spacing, while thin trapezoidal sheet needs closer purlins; otherwise the panel buckles when walked on. Cross bracing locks the roof laterally and prevents it from swaying in the wind; because it is not visible, it is the part most likely to be skipped, and the most expensive when it is. The details at the ridge, valleys and around chimneys are where leaks most often start, and they are resolved separately from the roofing. It can also be built on top of an existing reinforced concrete structure.
Materials used
- Trusses / lattice girders
- Purlins
- Cross bracing
- Sandwich panel or trapezoidal sheet
Profile sections and infill divisions are engineered according to the opening width, wind load and type of use; the values listed here are not a fixed commitment.
02Technical
Technical specifications
Since every piece is made to measure, dimensions are not standard; the fields in the table show which points are finalized during the site survey.
| Structure | Trusses / lattice girders, calculated for the span |
|---|---|
| Roofing | Sandwich panel, trapezoidal sheet or standing seam |
| Loads | Engineered for the region’s snow and wind loads |
| Critical detail | Cross bracing, ridge and valley solutions |
| Application | New build or on top of existing reinforced concrete |
03An honest note
When is this model not the right choice?
If the foundations and columns of the existing structure cannot carry the additional roof load, it cannot be applied; if the structural assessment is negative, strengthening is needed first. On very small spans, lattice trusses are not economical either; a box-section structure (SM-CT02) is sufficient.
Selling the wrong model does nobody any good. Send us the measurements and a photo of the installation site; if this model does not fit, we will tell you which one does.
04Matching set
Models used together at the same entrance
Because the driveway gate, pedestrian gate and railing stand side by side at the same entrance, they are made with the same profile thickness and the same surface finish.
Send measurements for SM-CT01
The width and height of the opening, the ground conditions and, if you have one, a photo of the installation site are enough. If a site survey is needed, we will let you know.