
Building and Villa Entrance Doors
A building entrance door is the first point of contact with a building: both its security boundary and the face it presents to the world. Because the door is made to measure, it is designed not on its own but together with its frame and the portal around it.
01Models
Building Entrance Doors models
Every model has a code. Sending us the code on WhatsApp is enough to make clear which model we are talking about.
5 models

Wood-Look Panel Villa Entrance Door
Building Entrance Doors · Walnut / oak-pattern panel, anthracite frame

Wrought Iron Glazed Entrance Door
Building Entrance Doors · Anthracite / navy body, gold wrought iron details

Modern Flush Entrance Door
Building Entrance Doors · Anthracite, gray or custom RAL

Classic Raised-Panel Apartment Entrance Door
Building Entrance Doors · Navy, anthracite or green

Double-Leaf Glazed Building Entrance Door
Building Entrance Doors · Anthracite or black profiles
02Definition
What is a building entrance door, and what does it solve?
A building entrance door is the main entrance door of a villa, an apartment building, a block in a residential complex or a facility. What sets it apart from an apartment’s interior door is that it stands outdoors and has to cope with shared use: it opens and closes many times a day, is exposed to rain and sun, takes wind load and often works together with a doorbell, intercom, camera and automatic door closer. That is why the frame, hinges and closing mechanism count as much as the leaf itself.
It is made to measure because entrance openings are not standard. At a villa entrance, the door is often more than just the leaf: there may be fixed glass or panels at the sides, a transom above and a stone- or composite-clad portal around it. When these are not all designed at the same time, the result is an entrance that looks pieced together, with joints that do not line up. We handle the door and the metal details around it in a single drawing.
The third deciding factor is wiring. Cable passages for the doorbell, intercom, camera, card access and electric lock are built in while the leaf and frame are being fabricated. Cables run afterward are either visible from outside or have to pass through the moving part of the leaf, where it eventually breaks. If an automatic door closer (hydraulic arm) is to be used, the hinges and frame reinforcement are chosen with it in mind from the start.
The mistake we see most often is choosing the door independently of the facade. When a flat-surfaced modern door is fitted to a stone-clad villa with classic lines, or a heavy wrought iron door to a plain reinforced concrete apartment building, the result is an entrance that speaks two different languages. During the site survey, we look at the facade material, the window frame color and the entrance overhang together.
03Types
Types of building entrance doors
The choice depends on the size of the entrance, the style of the facade and how many times a day the door will be used.
Single-leaf made-to-measure entrance door
The most common type. The leaf is a single piece, and there may be fixed panels or glass at the sides. It is used at villa and small apartment building entrances. As the leaf gets wider, the number of hinges and the frame reinforcement increase; a wide single leaf is the solution most prone to sagging over time, which is why the choice of hinges is critical.
Double-leaf entrance door
It is used at wide entrances and in buildings where furniture and goods need to be moved in and out. In daily use, one leaf operates while the second stays fixed with a bolt and is opened when needed. This gives a wide opening while keeping the door light in daily use.
Glazed entrance door
Part of the leaf is glazed to bring light into the entrance hall. On an exterior door, the glass is laminated or tempered — so that, if broken, it does not shatter and leave a security gap. As the glazed area grows, the leaf gets heavier and the hinge calculation changes.
Wood-look panel door
Wood-look composite or slat panels are applied over a metal body. It gives the look of wood without the maintenance wood demands: it does not crack, does not need varnishing every year and does not change color in the sun as much as real wood.
Entrance with portal and surrounding details
The door is designed together with the overhang above it and the clad portal around it. This lets the entrance read as a whole; when the doorbell, lighting and camera are placed on the portal, the leaf stays clean and no wiring passes through it.
04From the field
Projects we have completed
The photos below show Saray Metal’s own work; they are not illustrative images.
Building Entrance Doors
Composite-clad entrance portal Building entrance door Building entrance door Building entrance door Building entrance door Building entrance door Building entrance door Building entrance door
All photos are from Saray Metal’s own projects. Tap a photo to open it uncropped. If you would like to see more, message us on WhatsApp.
05Technical
Materials and technical specifications
Leaf thickness, frame section and hardware are determined according to the size of the door and how intensively it is used each day.
| Body | Box-section core frame + sheet or panel facing; section according to size |
|---|---|
| Door frame | Steel frame anchored to the wall; reinforced for wider leaves |
| Hinges | Adjustable; the number increases with leaf weight and width |
| Infill | Panel, slats, perforated sheet, glass (laminated/tempered) or wrought iron detail |
| Insulation | Insulation inside the leaf, plus seals; reduces heat loss and sound transmission |
| Lock | Multi-point locking or cylinder lock; electric lock together with a mechanical cylinder |
| Wiring | Cabling for the doorbell, intercom, camera and electric lock is routed during fabrication |
| Finish | Sandblasting + primer + electrostatic powder coating; choice of RAL color |
06Measurements
Measurement and planning
Measuring for an entrance door starts with checking each of the four corners of the opening separately; no entrance opening is perfectly rectangular. Then comes the floor: has the flooring been laid, and if not, how thick will it be, where will the threshold end, and is there a level difference in front of or behind the door? If the ground slopes from outside toward the inside, the threshold and seal details are designed so that water does not get in under the door.
The second step is intensity of use, and this determines the hardware. A villa door opened a few times a day and an apartment building door used by dozens of households do not take the same hinges or the same closer. For a door in shared use, a hydraulic closer, reinforced hinges and a more durable lock are preferred. The third step is the wiring plan: the cable route for the doorbell, intercom, camera and any card access is decided before the leaf and frame are fabricated.
Four corners and plumb
The opening is not perfectly rectangular; the four corners are measured separately, and plumb and level are checked.
Floor and threshold
Flooring thickness, level difference and the direction of water flow; the threshold and seal details are designed accordingly.
Intensity of use
How many times a day will it be opened? The number of hinges, the closer and the choice of lock follow from the answer.
Wiring route
Cabling for the doorbell, intercom, camera and electric lock is routed during fabrication; cables run afterward stay visible.
07Process
From site survey to handover
Every job goes through the same seven steps. When one of them is skipped, the problem usually shows up not during installation but at the end of the first year.
- 01
Site survey
Measurements are taken on site; we see the opening, level differences, ground conditions and any existing structure. The dimensions on paper almost never match those on site exactly.
- 02
Design and drawings
A technical drawing is prepared from the measurements. Infill divisions, profile sections and any automation layout are finalized at this stage.
- 03
Approval
The drawing and the color and material choices are approved in writing. Because a change after approval means reversing fabrication, this step is not rushed.
- 04
Fabrication
Cutting, bending and welding are done in our workshop in Arnavutköy. Weld seams are ground flush with the surface.
- 05
Surface treatment
The surface is prepared by sandblasting and primed, then electrostatic powder coating is applied. For parts that will stay outdoors, galvanizing comes into play.
- 06
Installation
On site, the work is anchored, aligned and, if needed, welded in place. If there is automation, the electrical connection and photocell adjustment are completed the same day.
- 07
Handover
Operation is checked, and use and maintenance are explained. Remote controls are programmed, locks are handed over and any phone app is set up at this stage.
08Price
What determines the price?
With an entrance door, the price is determined less by size than by the hardware and the number of details; this is where two doors of the same size can differ noticeably.
Size and number of leaves
Width and height; a double-leaf door needs more frame and hardware than a single leaf.
Infill type
Plain sheet, panel, wood-look slats, perforated sheet and glass fall into different cost classes.
Glazed area
As the area of laminated or tempered glass grows, both glass and hinge costs rise.
Lock and hardware
Multi-point locking, an electric lock and a hydraulic closer are separate items.
Portal and surrounding details
An overhang, side panels and a clad portal noticeably enlarge the scope.
Surface treatment
Sandblasting + primer + powder coating is standard; special textures and patina finishes are extra.
Installation conditions
If the existing door has to be removed, the frame replaced or the wall repaired, the scope grows.
09Maintenance
Maintenance and service life
With an entrance door, most of the maintenance concerns the moving parts. The hinges are checked once a year; if the door rubs as it closes or the latch has trouble engaging the strike, this is the first sign that the leaf is starting to sag, and with adjustable hinges it is solved with a simple adjustment. Leave it too late, and the frame comes under strain as well and the job gets bigger. Lock cylinders are lubricated with dry graphite; oily sprays attract dust and make sticking worse over time.
The second area is the seals and the surface. A worn seal leads to heat loss and lets rain in under the leaf; it is a replaceable part, and renewing it every few years is normal. Spots on the surface that have taken a knock and lost their paint should be touched up — especially near the threshold, the area worn most by cleaning water and de-icing salt. If there is an electric lock, make sure once a year that the mechanical cylinder also works; it is what you will use when the power goes out.
10FAQ
Frequently asked questions about Building Entrance Doors
Is a building entrance door the same as a steel door?
No, they are different lines of work. A steel door is a product whose body and hardware are largely standardized and which is made in set sizes. A building entrance door, on the other hand, is made to measure for the opening and designed together with the panel beside it, the transom above it and the portal around it. If your entrance is a standard opening and you are looking for a simple solution, you may also want to look at our Steel Doors page.
How do you keep the door from sagging?
Sagging almost always comes down to two causes: hinges that are inadequate for the weight of the leaf, and a frame that has not been anchored to the wall well enough. We choose the number and type of hinges according to the weight and width of the leaf, and we fabricate a reinforced frame for wide leaves. The hinges are adjustable; a check at the end of the first year is usually enough for trouble-free operation for the rest of the door’s life.
Is a glazed door safe?
Yes, if the right glass is chosen. Exterior doors use laminated or tempered glass: laminated glass is held together by its interlayer when broken and does not fall apart, while tempered glass breaks into small pieces without sharp edges. Plain annealed glass is never used. The size of the glazed area also comes into the hinge calculation, because it increases the weight of the leaf.
Do you prepare for a doorbell, camera and intercom?
Yes, and this needs to be planned from the start. Cable passages are built in while the leaf and frame are being fabricated; cables run afterward are either visible from outside or have to pass through the moving part of the leaf, where it eventually breaks. Tell us during the site survey which devices you will use, and we will leave the routes accordingly.
Can an electric lock be fitted?
It can, and it is common at apartment building and residential complex entrances. Our condition is this: an electric lock is always installed together with a mechanical cylinder. An entrance door that opens only electrically will leave you locked out during a power outage. The electrical preparation and the button/intercom connection are planned at the fabrication stage.
Can it replace my existing door?
Yes, this is work we do often. The old door and frame are removed, the opening is measured and the new door is made to that size. Because the wall may be damaged during removal, we assess any repair needs during the site survey. We do not recommend leaving the old frame in place and installing over it — that is where dimensions and insulation are compromised.
Can I choose the color and texture?
Yes. Electrostatic powder coating is applied in colors from the RAL chart, and there are also options with wood-look cladding. To match the facade, we usually suggest the existing window frame color or one shade darker. Color does not affect service life; what determines service life is that sandblasting and primer have not been skipped.
How long does delivery take?
The timeline is set by the drawing and approval stage after measurement, fabrication in the workshop and the surface treatment; installation is short by comparison. If surrounding details such as a portal and overhang are within the scope, it takes longer. We give the exact timeframe together with the quote, once the scope is clear.
11Related services
Work often done alongside this




14 / Contact
Send us your measurements for Building Entrance Doors
Approximate measurements and your district are enough for us to outline the quote. Let’s set the best day for the site survey in the same conversation.