Skip to content
Steel fire escape stair on a building facade

Fire Escape Stair Fabrication

A fire escape stair is an escape route built so that the people in a building can get outside. What sets it apart from other metalwork is that its form is determined by regulations, not by design preference: tread dimensions, width, railing height and door swing are not open to choice.

01Models

Fire Escape Stairs models

Every model has a code. Sending us the code on WhatsApp is enough to make clear which model we are talking about.

02Definition

What is a fire escape stair, and when is one required?

A fire escape stair is the second escape route that comes into play when the building’s regular stair can no longer be used. Its purpose is not aesthetics or access but evacuation time: making sure the people inside can reach the outside without being affected by smoke, without bottlenecks and without losing their way in the dark. That is why the stair’s dimensions are determined not by user comfort but by how quickly a crowd can flow through it.

Whether one is required is determined jointly by the building height, the number of floors, the occupancy class (residential, workplace, hotel, healthcare, education, industrial) and the number of people on each floor. It is not a matter of choice, and we cannot give definitive information on it either — whether you need one and which class you fall into is determined by the fire department or the relevant municipal office. Most of the jobs that come to us are ones where this determination has already been made, that is, jobs at the “a fire escape stair has been required” stage.

The items set by the regulations are, roughly: stair width, tread depth and riser height, landing size, railing height and infill spacing, the opening direction of the escape doors, and the stair discharging into a safe area. None of these can be changed by saying “space is tight, let’s trim it a little”; if they are changed, the stair is built but becomes useless, and it will not pass inspection.

Steel fire escape stairs are common because they can be added to an existing building. When the building is finished, the concrete has been poured and there is no space left inside, a steel stair attached to the exterior facade is often the only workable solution. It is prepared in the workshop and installed on site, and the building stays in use throughout.

03Types

Fire escape stair types

The type is chosen according to the building height, the space available on the facade and the position of the escape doors.

Multi-flight exterior stair

The most common solution. The flights are connected by landings, and on each floor a landing meets an escape door. It needs a certain amount of space on the facade; in return, it is spacious, comfortable and the type best suited to evacuation.

Single-flight straight stair for narrow facades

If horizontal space on the facade is limited, the flights are extended along a single line. Because the total length increases, the structure and anchoring are distributed over more points. The landing positions are drawn together with the escape doors.

Spiral stair

Used in very tight spaces. It saves space, but the flow rate in a crowded evacuation is low, and it is not accepted for every occupancy class. When it counts as sufficient depends on the regulations; we do not recommend it where it is not suitable.

Escape platforms and connecting bridges

The route leading to the stair is as much a part of the escape route as the stair itself. Attic passages, bridges between two blocks and platforms outside doors are built within this scope; the railing and floor details meet the same standard as the stair.

Service and escape stairs in industrial buildings

In warehouses, factories and buildings with mezzanines, the escape stair is often planned together with service access. Steel grating treads are chosen — they don’t collect water or snow, they reduce slipping, and in a fire they let smoke pass through instead of building up on the treads.

04From the field

Projects we have completed

The photos below show Saray Metal’s own work; they are not illustrative images.

Fire Escape Stairs

  • Fire escape stair installation
  • Steel stair fabrication

All photos are from Saray Metal’s own projects. Tap a photo to open it uncropped. If you would like to see more, message us on WhatsApp.

05Technical

Materials and technical specifications

The dimensions are set by regulation; the table below shows which items are finalized in the design.

StructureColumns + beams + stringers; section according to height and load
TreadsSteel grating (does not collect water) or diamond plate; both reduce slipping
Tread dimensionsTread depth and riser height set by regulation
LandingsMeet an escape door on every floor; size set by regulation
RailingHeight and infill spacing set by regulation; no horizontal rails that make climbing easier
Escape doorOpens in the direction of escape; panic bar requirement depends on the occupancy class
AnchoringPlates and anchors into the facade; the surface is checked to confirm it is reinforced concrete and has the bearing capacity
FinishHot-dip galvanizing + paint; lasting protection outdoors

06Measurements

Measurement and planning

With a fire escape stair, planning starts with the doors, not the stair. The position and level of the escape door on each floor are determined; the landings are placed to meet these doors, and the flights run between the landings. Doing it the other way round — placing the stair first and then trying to open up doors — often ends with a door in the wrong place and a broken escape route.

The second step is the facade and anchoring. Since the stair’s load is transferred to the facade through anchors, the surface must be reinforced concrete, with a structural member at that point; anchors are not fixed into infill walls or over exterior insulation. If there is exterior insulation, the anchor must pass through the insulation to reach the structure, and the thermal bridge detail has to be resolved. Then there is the ground: where the foot of the stair will land, whether the exit point opens onto a safe area, and whether there is vehicle traffic or an obstruction there — these are checked on site during the survey.

  • Escape doors and levels

    The position and level of the door on each floor are determined first; the landings are placed according to these doors.

  • Facade and anchor points

    Anchors go into the reinforced concrete structure; infill walls and exterior insulation are not accepted as anchoring surfaces.

  • Exit point

    The point where the stair ends must open onto a safe area, with no obstructions or vehicle traffic in front of it.

  • Regulatory dimensions

    Width, tread, landing and railing dimensions come from the regulations; they are not reduced on the grounds that space is tight.

07Process

From site survey to handover

Every job goes through the same seven steps. When one of them is skipped, the problem usually shows up not during installation but at the end of the first year.

  1. 01

    Site survey

    Measurements are taken on site; we see the opening, level differences, ground conditions and any existing structure. The dimensions on paper almost never match those on site exactly.

  2. 02

    Design and drawings

    A technical drawing is prepared from the measurements. Infill divisions, profile sections and any automation layout are finalized at this stage.

  3. 03

    Approval

    The drawing and the color and material choices are approved in writing. Because a change after approval means reversing fabrication, this step is not rushed.

  4. 04

    Fabrication

    Cutting, bending and welding are done in our workshop in Arnavutköy. Weld seams are ground flush with the surface.

  5. 05

    Surface treatment

    The surface is prepared by sandblasting and primed, then electrostatic powder coating is applied. For parts that will stay outdoors, galvanizing comes into play.

  6. 06

    Installation

    On site, the work is anchored, aligned and, if needed, welded in place. If there is automation, the electrical connection and photocell adjustment are completed the same day.

  7. 07

    Handover

    Operation is checked, and use and maintenance are explained. Remote controls are programmed, locks are handed over and any phone app is set up at this stage.

08Price

What determines the price?

With fire escape stairs, the number of floors seems to be what determines the cost; in reality, what decides it is which type and which anchoring conditions are used to cover the same height.

  • Total height and number of floors

    The basic item that directly determines the number of flights and landings.

  • Stair type

    Multi-flight, single-flight straight and spiral stairs mean different materials and different labor.

  • Width

    As the width required by the regulations increases, the treads, landings and structure all grow together.

  • Anchoring conditions

    An insulated facade, a weak surface or the need for separate supporting columns expands the scope.

  • Treads and railings

    Steel grating, diamond plate and the type of railing infill fall into different cost classes.

  • Surface treatment

    Hot-dip galvanizing + paint is the item that determines service life outdoors.

  • Installation conditions

    Height, the need for a crane or bucket truck, and the work plan while the building remains in use.

09Maintenance

Maintenance and service life

A fire escape stair is built on the assumption that it may not be used even once a year — and that is exactly why it needs regular checks: when it deteriorates, no one notices. Once a year, check for loosening or plaster cracks at the anchor points, loosening at the tread attachments, play in the railing connections, and spots where the paint has chipped and rust has started. With galvanized fabrication this risk is low, but it is not zero.

The second, and often more critical, issue is keeping the escape route clear. Materials stored on the landings, vehicles parked under the stair, escape doors locked or tied shut — all of these make the stair useless, and none of them has anything to do with the metal. In day-to-day operation, keeping these areas clear matters more than maintaining the stair itself. Also check regularly that the escape doors open in the direction of escape and are not locked from the outside.

10FAQ

Frequently asked questions about Fire Escape Stairs

  • Does my building need a fire escape stair?

    That is not something we can determine. The requirement is set by regulations based on the building height, number of floors, occupancy class and number of people on each floor; the definitive answer comes from the fire department or the relevant municipal office. Come to us with the determination you receive from them, and we will plan the dimensions and installation accordingly.

  • Can we reduce the dimensions? There’s no room on the facade.

    No. The width, tread dimensions, landings and railing height come from the regulations and are not reduced on the grounds that space is tight; if they are reduced, the stair gets built but won’t pass inspection and won’t do its real job. If space is tight, the solution is not to cut the dimensions but to change the stair type: a single-flight straight layout or a different division of the flights often works.

  • Can one be added to an existing building?

    Yes, that is the most common use of a steel fire escape stair. The stair is prepared in the workshop, anchored to the facade, and the building stays in use throughout. The deciding factor is whether the facade can carry the anchors — anchors go into the reinforced concrete structure, not into infill walls or over the exterior insulation. We check this during the site survey.

  • Can it be installed on an insulated facade?

    It can, but it requires additional detailing: the anchor must pass through the insulation layer to reach the reinforced concrete structure, and the thermal bridge at that point must be resolved. A stair anchored over the insulation will work loose over time and damage the insulation as well. We plan this detail from the start.

  • Why galvanizing?

    A fire escape stair stands outdoors for years, under rain and snow, and often no one looks at it. With painted steel, corrosion starts at the joints and goes unnoticed; in a structure that has to be sound on the day it is needed, this is unacceptable. Since hot-dip galvanizing also protects cut and scratched spots, it is our standard choice.

  • Does the tread type matter?

    It does. Steel grating doesn’t collect water or snow, reduces slipping, and is preferred on exterior stairs because it lets smoke pass through. Diamond plate gives a more closed surface and is called for in some uses. Which one is appropriate is determined by the building type together with the regulations.

  • How long does it take to complete?

    The timeline is driven by design approval, workshop fabrication and the galvanizing process; installation on site is short by comparison. If the work is done while the building is in use, the installation plan also affects the timeline. Since the exact timeline depends on the number of floors, the type and the anchoring conditions, we give it together with the quote.

  • Do you prepare the design?

    We prepare the construction drawings and the structural calculations. The fire protection design and the approval process, however, are handled by the designer of record and the fire department; we provide the technical documents that process requires. We don’t start fabrication without approval — a stair whose dimensions have to be changed afterward usually has to be rebuilt.

11Guides

Read before you decide

Topics that come up often at the decision stage and fall outside the technical scope of this page.

14 / Contact

Send us your measurements for Fire Escape Stairs

Approximate measurements and your district are enough for us to outline the quote. Let’s set the best day for the site survey in the same conversation.