Skip to content

Single-Leaf Fire Door with Panic Bar

A single-leaf door with a panic bar for stairwells and escape corridors.

Color
Light gray; RAL of your choice
Opening type
Single leaf
Style
Minimal
SM-YK001 light gray single-leaf fire door with a horizontal panic bar and fire exit sign

01Model

What is this model for?

The entrance to a stairwell is one of the most important doors in a building, yet the least considered: people pass through it hundreds of times a day, and no one looks at it until a fire breaks out. This model is made for exactly that spot: a single-leaf door with a panic bar that opens in the direction of escape. Thanks to the panic bar, even someone unfamiliar with the door — in the dark, in smoke, with a crowd behind them — opens it by pushing on the bar, without searching for a handle. The door closer shuts the leaf after every passage and engages the latch; a fire door’s job is to stay closed, and it does not leave that to the user’s memory. Light gray sits in stairwells and corridors without clashing with the wall color; the fire exit sign on the door shows the direction. Your building’s fire safety design determines which fire resistance class it needs; the door is selected for that class and for the opening in the wall.

Materials used

  • Steel frame and leaf
  • Fire-resistant leaf core
  • Intumescent seal

Profile sections and infill divisions are engineered according to the opening width, wind load and type of use; the values listed here are not a fixed commitment.

02Technical

Technical specifications

Since every piece is made to measure, dimensions are not standard; the fields in the table show which points are finalized during the site survey.

LeafSingle leaf, opens in the direction of escape
Escape hardwareHorizontal panic bar — opens in a single movement
ClosingDoor closer; closes by itself after every passage
Fire ratingSelected for the class required by the fire safety design
UseStairwell, escape corridor, compartment door
SizeWithin the size range in which the door was tested

03An honest note

When is this model not the right choice?

If the door is not on an escape route and the fire safety design does not call for a fire door at that point — an ordinary office, storage or apartment door — a fire door is an unnecessary cost; the flush steel door (SM-CK002) does the job. If the door needs to stay open all day, this model alone is not enough: an alarm-linked magnetic hold-open device should be added.

Selling the wrong model does nobody any good. Send us the measurements and a photo of the installation site; if this model does not fit, we will tell you which one does.

04Matching set

Models used together at the same entrance

Because the driveway gate, pedestrian gate and railing stand side by side at the same entrance, they are made with the same profile thickness and the same surface finish.

Send measurements for SM-YK001

The width and height of the opening, the ground conditions and, if you have one, a photo of the installation site are enough. If a site survey is needed, we will let you know.